Search Manual / Version 2110
Table Of ContentsThe CAE Feeder persists the feeding state in a database. Configure the connection to the database with the following properties:
jdbc.driver
- Specifies the class of the database driver
jdbc.url
- Contains the URL of the database
jdbc.user
- Specifies the account name of the database user
jdbc.login-user-name
- Specifies the login name of the database user. Defaults to jdbc.user. In some cases the login username differs from the actual user, for example, with PostgreSQL on Azure a postfix on the user name is necessary to log in. Set this property additionally to jdbc.user.
jdbc.password
- Specifies the account password of the database user
For example:
jdbc.driver=oracle.jdbc.driver.OracleDriver jdbc.url=jdbc:oracle:thin:@localhost:1521:oracle jdbc.user=username jdbc.password=password # Additional property for PostgreSQL on Azure #jdbc.login-user-name=username@domain
Example 5.2. Configure the database
Note
To avoid performance problems with Microsoft SQL Server, it is recommended to set the connection property
sendStringParametersAsUnicode=false
as part of the configured
jdbc.url
, for example:
jdbc:sqlserver://localhost:1433;databaseName=cm_mcaefeeder;sendStringParametersAsUnicode=false
.
For more details, see the Microsoft SQL Server documentation.
Caution
Do not run multiple CAE Feeder applications on the same database schema.